JLG 4017PS Service Manual User Manual

Page 254

Advertising
background image

Electrical System

9-96

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

1098

523718

5

6-7-6

SCR-heater external relay; open load

1100

523718

3

6-7-6

SCR-heater external relay; short circuit to battery

1101

523718

4

6-7-6

SCR-heater external relay; short circuit to ground

1102

4341

5

6-7-5

SCR-heater urea supply line; open load

1104

4341

3

6-7-5

SCR-heater urea supply line; short circuit to battery

1105

4341

4

6-7-5

SCR-heater urea supply line; short circuit to ground

1106

523719

5

6-7-2

SCR-heater urea supply line; open load

1108

523719

3

6-7-2

SCR-heater urea supply module; short circuit to battery

1109

523719

4

6-7-2

SCR-heater urea supply module; short circuit to ground

1110

4366

5

6-7-1

SCR-heater urea tank; open load

1111

4366

12

6-7-1

SCR-heater relay urea tank powerstage output; over temperature

1112

4366

3

6-7-1

SCR-heater urea tank; short circuit to battery

1113

4366

4

6-7-1

SCR-heater urea tank; short circuit to ground

1118

4375

5

6-6-6

Urea pump motor; open load

1120

4375

3

6-6-6

Urea pump motor; short circuit to battery

1121

4375

4

6-6-6

Urea pump motor; short circuit to ground

1122

4334

0

6-6-5

Physical range check high for Urea Pump Pressure

1123

4334

1

6-6-5

Physical range check low for Urea Pump Pressure

1124

4334

0

6-6-5

Sensor error urea pump pressure; signal range check high before
pressure build up

1125

4334

1

6-6-5

Ad Blue pump pressure: signal range before pressure build up is
below minimum

1127

4334

3

6-6-5

Sensor error urea pump pressure; signal range check high

1128

4334

4

6-6-5

Sensor error urea pump pressure; signal range check low

1129

4376

5

6-6-7

SCR reversing valve; open load

1130

4376

12

6-6-7

SCR reversing valve; over temperature

1131

4376

3

6-6-7

SCR reversing valve; short circuit to battery

1132

4376

4

6-6-7

SCR reversing valve; short circuit to ground

1135

3031

0

6-6-9

Ad Blue-Tank temperature: maximum exceeded

1136

3031

1

6-6-9

DEF-Tank temperature: below minimum

1138

3031

3

6-6-9

Sensor error urea tank temperature; short circuit to battery

Advertising
This manual is related to the following products: