Electrical system – JLG 4017PS Service Manual User Manual

Page 221

Advertising
background image

9-63

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

AUXILIARY

FUNCTION-A/B

VALVES – SHORT

TO BATTERY

33197

Continuously

Auxiliary Function-A is prevented

Auxiliary Function-B is prevented

UGM J3-14 Aux Return is disabled

Continuous Auxiliary Hydraulics is

prevented

Hydraulic Quick Connect is

prevented

Auxiliary Release is prevented

Short to battery is detected on

UGM J2-9 or UGM J2-20

Power cycled

AUXILIARY

FUNCTION-A

VALVE – SHORT

TO GROUND

33198

Continuously

Auxiliary Function-A is prevented

Auxiliary Function-B is prevented

UGM J3-14 Aux Return is disabled

Continuous Auxiliary Hydraulics is

prevented

Hydraulic Quick Connect is

prevented

Auxiliary Release is prevented

Short to ground is detected on

UGM J2-9

Power cycled

AUXILIARY

FUNCTION-B

VALVE – OPEN

CIRCUIT

33199

5000mS

Auxiliary Function-B is prevented

Continuous Auxiliary Hydraulics is

prevented

Hydraulic Quick Connect is

prevented

Auxiliary Release is prevented

Open-circuit is detected on UGM

J2-20

Power cycled

AUXILIARY

FUNCTION-B

VALVE – SHORT

TO GROUND

33200

Continuously

Auxiliary Function-A is prevented

Auxiliary Function-B is prevented

UGM J3-14 Aux Return is disabled

Continuous Auxiliary Hydraulics is

prevented

Hydraulic Quick Connect is

prevented

Auxiliary Release is prevented

Short to ground is detected on

UGM J2-20

Power cycled

STABILIZER/

FRAME LEVEL

SPEED VALVE –

OPEN CIRCUIT

33201

5000mS

Stabilizers are prevented

Frame Level is prevented

Cabin Mode; Machine Setup’s

MODEL is 4014 or 4017; open-

circuit is detected on UGM J1-3

Power cycled

STABILIZER/

FRAME LEVEL

SPEED VALVE –

SHORT TO

BATTERY

33202

Continuously

Stabilizers are prevented

Frame Level is prevented

UGM J3-5 Stabilizer / Frame Level

Speed Return is disabled

Cabin Mode; Machine Setup’s

MODEL is 4014 or 4017; short to

battery is detected on UGM J1-3

Power cycled

STABILIZER/

FRAME LEVEL

SPEED VALVE –

SHORT TO

GROUND

33203

Continuously

Stabilizers are prevented

Frame Level is prevented

UGM J3-5 Stabilizer / Frame Level

Speed Return is disabled

Cabin Mode; Machine Setup’s

MODEL is 4014 or 4017; short to

ground is detected on UGM J1-3

Power cycled

HYDRAULIC

QUICK CONNECT

SELECT – OPEN

CIRCUIT

33204

5000mS

Hydraulic Quick Connect is

prevented

Machine Setup’s HYDRAULIC

QUICK CONNECT is YES; open-

circuit is detected on UGM J1-23

Power cycled

Advertising