9-81

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

111

523931

0

7-2-4

Fuel Balance Control integrator injector 3 (in firing order);
maximum value exceeded

112

523932

0

7-2-4

Fuel Balance Control integrator injector 4 (in firing order);
maximum value exceeded

113

523933

0

7-2-4

Fuel Balance Control integrator injector 5 (in firing order);
maximum value exceeded

114

523934

0

7-2-4

Fuel Balance Control integrator injector 6 (in firing order);
maximum value exceeded

115

523929

1

7-2-4

Fuel Balance Control integrator injector 1 (in firing order); minimum
value exceeded

116

523930

1

7-2-4

Fuel Balance Control integrator injector 2 (in firing order); minimum
value exceeded

117

523931

1

7-2-4

Fuel Balance Control integrator injector 3 (in firing order); minimum
value exceeded

118

523932

1

7-2-4

Fuel Balance Control integrator injector 4 (in firing order); minimum
value exceeded

119

523933

1

7-2-4

Fuel Balance Control integrator injector 5 (in firing order); minimum
value exceeded

120

523934

1

7-2-4

Fuel Balance Control integrator injector 6 (in firing order); minimum
value exceeded

121

1109

2

3-4-1

Engine shut off demand ignored

122

523698

11

5-9-1

Shut off request from supervisory monitoring function

126

523603

9

3-3-8

Time out Error of CAN-Receive-Frame AMB;
Ambient Temperature Sensor

128

3224

9

5-9-7

Time out Error of CAN-Receive-Frame AT1IG1;
NOX sensor upstream

129

3224

2

5-9-6

DLC Error of CAN-Receive-Frame AT1IG1Vol NOX Sensor (SCR-
system upstream cat; DPF- system downstream cat); length of
frame incorrect

130

3224

9

5-9-7

Time out Error of CAN-Receive-Frame AT1IG1Vol; NOX sensor
(SCR-system upstream cat; DPF- system downstream cat)

133

523938

9

7-6-6

Time out Error (BAM to packet) for CAN-Receive- Frame
AT1IGCVol1 information; factors & Sensor calibration for NOX
Sensor (SCR-system upstream cat; DPF-system downstream cat)

134

523939

9

7-6-6

Time out Error (BAM to BAM) for CAN-Receive- Frame
AT1IGCVol1 information; factors & Sensor calibration for NOX
Sensor (SCR-system upstream cat; DPF-system downstream cat)