9-97

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

1139

3031

4

6-6-9

Sensor error urea tank temperature; short circuit to ground

1157

97

12

2-2-8

Water in fuel level prefilter; maximum value exceeded

1158

523946

0

7-7-2

Zero fuel calibration injector 1 (in firing order);
maximum value exceeded

1159

523947

0

7-7-2

Zero fuel calibration injector 2 (in firing order);
maximum value exceeded

1160

523948

0

7-7-2

Zero fuel calibration injector 3 (in firing order);
maximum value exceeded

1161

523949

0

7-7-2

Zero fuel calibration injector 4 (in firing order);
maximum value exceeded

1162

523950

0

7-7-2

Zero fuel calibration injector 5 (in firing order);
maximum value exceeded

1163

523951

0

7-7-2

Zero fuel calibration injector 6 (in firing order);
maximum value exceeded

1164

523946

1

7-7-2

Zero fuel calibration injector 1 (in firing order);
minimum value exceeded

1165

523947

1

7-7-2

Zero fuel calibration injector 2 (in firing order);
minimum value exceeded

1166

523948

1

7-7-2

Zero fuel calibration injector 3 (in firing order);
minimum value exceeded

1167

523949

1

7-7-2

Zero fuel calibration injector 4 (in firing order);
minimum value exceeded

1168

523950

1

7-7-2

Zero fuel calibration injector 5 (in firing order);
minimum value exceeded

1169

523951

1

7-7-2

Zero fuel calibration injector 6 (in firing order);
minimum value exceeded

1170

523612

12

5-5-5

Internal software error ECU

1171

175

2

1-4-4

Customer oil temperature: signal unplausible

1173

523973

14

7-7-9

SCR Tamper detection; derating timer below limit 1

1174

523974

14

7-7-9

SCR Tamper detection; derating timer below limit 2

1175

523975

14

7-8-0

Urea quality; derating timer below limit 1

1176

523976

14

7-8-0

Urea quality; derating timer below limit 2

1177

523977

14

7-8-1

Urea tank level; derating timer below limit 1

1178

523978

14

7-8-1

Urea tank level; derating timer below limit 2

1180

168

0

3-1-8

Physical range check high for battery voltage

1181

168

1

3-1-8

Physical range check low for battery voltage