Electrical system – JLG 4017PS Service Manual User Manual

Page 228

Advertising
background image

Electrical System

9-70

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

g. Transmission & Drive System (46X)

REFERENCE

VOLTAGE OUT

OF RANGE –

TCM

4423

5000mS

Hydraulic Variable Speed operates

at maximum speed; Hydraulic Fan

Reversing is prevented

Hydraulic Variable Speed Fan is

configured;

TCM detects its reference

voltage is out of range (>5.4V or

<4.6V) for 1000mS

Power cycled

TRANSMISSION

&

DRIVE SYSTEM

46XXX

-

-

-

-

HIGH

TRANSMISSION

OIL

TEMPERATURE

CRITICAL

461

Continuously

Transmission oil temperature is

critical

Transmission

oil temperature

is normal

VEHICLE SPEED

SENSOR – NOT

RESPONDING

468

5000mS

·

Display “99” as Vehicle

Speed on cabin display

·

Restrict direction and gear

selection to present state or
associated neutral state when this
occurs during operation

·

Retain this fault through

power cycles

·

Restrict direction and gear

selection to F3, N3, R2 (Platform
Gear Restriction is not active) if this
fault is active from the previous
power cycle

·

and Machine Setup’s

TRANSMISSION is TURNER 6F/3R.

·

Restrict direction and gear

selection to F2, N2, R2 (Platform
Gear Restriction is not active) if this
fault is active from the previous
power cycle and Machine Setup’s
TRANSMISSION is TURNER 4F/3R.

Direction Selection is Forward or

Reverse;

Park Brake is not engaged;

Service Brake is not applied;

Engine RPM >1000 RPM;

No vehicle speed counts >

40,000mS

Vehicle speed

counts

detected for

5,000mS

VEHICLE

OVERSPEED

469

Continuously

·

Flash Vehicle Speed on

cabin display

Vehicle speed is greater than

43KPH

Vehicle speed

below

threshold for

1000mS

PUMP

DISPLACEMENT
VALVE – SHORT

TO BATTERY OR

OPEN CIRCUIT

4618

5000mS

Anti-Stall functionality is enabled;

short to battery or open-circuit is

detected on TCM J5-1 for

1,000mS

Power cycled

PUMP

DISPLACEMENT
VALVE – SHORT

TO GROUND

4619

5000mS

Anti-Stall functionality is enabled;

short to ground is detected on

TCM J5-1 at power-up

Power cycled