6 operator tools, 1 resetting the anti theft code, 2 hardware exchange – JLG 4017PS Service Manual User Manual

Page 169: Operator tools, Resetting the anti theft code, Hardware exchange

Advertising
background image

9-11

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

9.6

OPERATOR TOOLS

9.6.1

Resetting the Anti theft Code

To reset the anti theft code:

1. Turn the engine to the ON position.

2. Press the "C" and "OK" buttons on the dash

simultaneously to enter the analyzer mode.

3. Scroll to "Access Level Code". Enter the code

"33271" to go into access level 2.

4. Scroll to and select the "Operator Tools" screen.

5. Scroll to and select the "Change Anti Theft Code"

screen.

6. Enter the current anti theft code.

Note: If a machine does not have an anti theft code set,
the default code is "00000".

7. Enter the new code.

9.6.2

Hardware Exchange

After the replacement of either the display or UGM
(Controller) the machine software will indicate a
Hardware Exchange fault. To correct this fault:

1. Turn the engine to the ON position.

2. Press the "C" and "OK" buttons on the dash

simultaneously to enter the analyzer mode.

Calibrations:
Park Brake
Test

Perform Park
Brake Test?

Access Levels
1,2,3

Used by customers (mining) as part of a daily safety
verification that the vehicle cannot drive through the
parking brake in second gear; interlocks that prevent
gear engagement while the parking brake is set are
ignored; press ENTER to continue or ESC to exit

Set Park Brake

Prompt user to apply the park brake; brake must
remain applied during test unless shifter returns to
neutral

Shift To Second
Gear

Prompt user to select second gear

Warning: Drive
Will Be Engaged

Prompt user that the vehicle will engage the
transmission (attempt to drive through park brake)
during the next step

Forward To Start
Neutral To Pause

Prompt user to select forward direction for evaluation

Park Brake Test
Complete

The evaluation was successful; press ESC to exit

Park Brake Test
Failed

The CABIN JOYSTICK – FNR SWITCH FAULT
(23115) fault was active and the test could not
proceed; press ESC to exit

Calibrations:
Trans Service

Confirm Trans
Service: No

Access Levels
1,2

UP and DOWN select NO or YES; default to NO at
power-up

Confirm Trans
Service: Yes

When YES, allow Direction Selection despite faults
detected so a technician can diagnose or transport a
vehicle

Calibrations:
Fan Speed
Test

Perform Fan
Speed Test?

Access Levels
1,2; Hydraulic
Variable Speed
Fan Configured

Used by technicians at the factory for noise testing;
press ENTER to begin or ESC to exit

Fan Speed Valve
0 Ma

UP and DOWN keys directly adjust fan speed valve
current with 50mA increments (3000mA maximum);
default is 0mA (highest fan speed) to start test; fan
reversing is prevented once test begins; selected fan
speed valve current is retained until power is cycled

Advertising