3 confirm machine service, 4 review service history, 5 set service interval – JLG 4017PS Service Manual User Manual

Page 170: 6 cabin joystick telescope: x-axis/ roller, Confirm machine service, Review service history, Set service interval, Cabin joystick telescope: x-axis/roller

Advertising
background image

Electrical System

9-12

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

3. Scroll to "Access Level Code". Enter the code

"33271" to go into access level 2.

4. Scroll to and select the "Operator Tools" screen.

5. Scroll to and select the "Perform Hardware

Exchange" screen.

6. Scroll to and select the proper screen for hardware

exchange. The screen will show either
"DISPLAY -> UGM" or "UGM -> DISPLAY". The new
component should be listed second.

9.6.3

Confirm Machine Service

To log the machine service into the software:

1. Turn the engine to the ON position.

2. Press the "C" and "OK" buttons on the dash

simultaneously to enter the analyzer mode.

3. Scroll to "Access Level Code". Enter the code

"33271" to go into access level 2.

4. Scroll to and select the "Operator Tools" screen.

5. Scroll to and select the "Confirm Machine Service"

screen.

6. If service is complete, press ENTER for YES.

Otherwise, press ESC for NO.

9.6.4

Review Service History

To view the last 15 machine service instances:

1. Turn the engine to the ON position.

2. Press the "C" and "OK" buttons on the dash

simultaneously to enter the analyzer mode.

3. Scroll to "Access Level Code". Enter the code

"33271" to go into access level 2.

4. Scroll to and select the "Operator Tools" screen.

5. Scroll to and select the "Review Service History"

screen.

6. Scroll through the screens to view the last 15 times

the machine was serviced.

9.6.5

Set Service Interval

To set the machine recommended service interval:

1. Turn the engine to the ON position.

2. Press the "C" and "OK" buttons on the dash

simultaneously to enter the analyzer mode.

3. Scroll to "Access Level Code". Enter the code

"33271" to go into access level 2.

4. Scroll to and select the "Operator Tools" screen.

5. Scroll to and select the "Set Service Interval" screen.

6. Enter a new service interval.

9.6.6

Cabin Joystick Telescope: X-Axis/
Roller

To change the joystick telescope function on the joystick:

1. Turn the engine to the ON position.

2. Press the "C" and "OK" buttons on the dash

simultaneously to enter the analyzer mode.

3. Scroll to "Access Level Code". Enter the code

"33271" to go into access level 2.

4. Scroll to and select the "Operator Tools" screen.

5. Scroll to and select the "Cabin Joystick Telescope"

screen.

6. Select either X-AXIS or ROLLER.

When changing the joystick function, ensure the correct
joystick operation decal is installed. Contact the local JLG
dealer.

Advertising