9-51

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

9.18.2

Machine Fault Codes

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

HELP COMMENT

00XXX

EVERYTHING OK

001

The system detects no problems

exist.

POWER UP

21XXX

POWER CYCLE

211

-

-

Power was cycled ON.

-

FUNCTION

ENABLE INPUTS –

INVALID SIGNAL

STATES

214

Continuously

PLT J2-19 Function Enable Relay

shall be de-energized

Platform controls shall be

prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; Platform

Mode; Key switch Platform; PLT J2-

19 Function Enable Relay is

energized; PLT J7-8 & UGM J7-15

Function Enable Switch digital

inputs are not complementary for

1000mS

Machine Setup’s PLATFORM

OPTION is ENABLED; Platform

Mode; Key switch Platform;

power-up; PLT J7-8 Function

Enable Switch digital input is

energized

Power cycled

JOYSTICK AXES

NOT IN NEUTRAL

POSITION AT

POWER UP

215

5000mS

The cabin joystick X & Y axis input

shall be ignored

The cabin joystick’s X or Y axis is

not neutral at power-up

The cabin

joystick’s X

and Y axis

return to

neutral

JOYSTICK S1

BUTTON ACTIVE

AT POWER UP

217

5000mS

The cabin joystick S1 push button

(downshift) is prevented

The cabin joystick’s S1 push button

(downshift) is pressed at power-up

The push

button is
released

JOYSTICK S2

BUTTON ACTIVE

AT POWER UP

218

5000mS

The cabin joystick S2 push button

(upshift) is prevented

The cabin joystick’s S2 push button

(upshift) is pressed at power-up

The push

button is
released

ENGINE START

PREVENTED –

PLATFORM

START SWITCH

HIGH AT POWER

UP

2111

5000mS

Platform Engine Start is prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; Platform

Mode; PLT J1-14 Engine Start

Switch is closed at power-up

The switch is

open

momentarily

PLATFORM

ROTATE LEFT

PREVENTED –

INPUT HIGH AT

POWER UP

2112

5000mS

Platform Rotate Left & Right are

prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; Platform

Mode; PLT J1-8 Platform Rotate

Left Switch is closed at power-up

Power cycled

PLATFORM

ROTATE RIGHT

PREVENTED –

INPUT HIGH AT

POWER UP

2113

5000mS

Platform Rotate Left & Right are

prevented

Machine Setup’s PLATFORM

OPTION is ENABLED; Platform

Mode; PLT J1-7 Platform Rotate

Right Switch is closed at power-up