3 engine fault codes, Engine fault codes – JLG 4017PS Service Manual User Manual

Page 237

Advertising
background image

9-79

3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7

Electrical System

9.18.3

Engine Fault Codes

FUNCTIONS

LOCKED OUT –

TCM

SOFTWARE

VERSION

IMPROPER

99163

Continuously

·Hydraulic functions are prevented

·Engine Start is prevented

·

·UGM J4-12 ECM / Fuel Relay is

energized to shutdown engine

TCM transmitted a Major Software

version that is not compatible (P4.x

allowed)

Power cycled

KWP

SPN

FMI

Blinkcode

Message

1

132

11

2-2-6

Air flow sensor load correction factor exceeding the maximum drift
limit; plausibility error

2

132

11

2-2-6

Air flow sensor load correction factor exceeding drift limit;
plausibility error

3

132

11

2-2-6

Air flow sensor low idle correction factor exceeding the maximum
drift limit

4

132

11

2-2-6

Air flow sensor load correction factor exceeding the maximum drift
limit

9

172

2

2-2-6

Sensor ambient air temperature; plausibility error

34

523006

3

2-4-2

Controller mode switch; short circuit to battery

35

523006

4

2-4-2

Controller mode switch; short circuit to ground

45

168

3

3-1-8

Sensor error battery voltage; signal range check high

46

168

4

3-1-8

Sensor error battery voltage; signal range check low

47

168

2

3-1-8

High battery voltage; warning threshold exceeded

48

168

2

3-1-8

Low battery voltage; warning threshold exceeded

49

597

2

3-2-1

Break lever main switch and break lever redundancy switch status
not plausible

55

523910

14

6-9-5

Air pump doesn't achieve air mass flow set point

56

524013

7

8-5-6

Burner flame unintentional deleted

57

524020

14

8-6-3

Engine power reduction due to low lambda

58

523911

0

7-2-3

Burner dosing valve (DV2); over current at the end of the injection
phase

59

523911

12

7-2-3

Burner dosing valve (DV2); powerstage over temperature

60

523911

3

7-2-3

Burner dosing valve (DV2); short circuit to battery

61

523911

3

7-2-3

Burner dosing valve (DV2); short circuit to battery on high side

62

523911

4

7-2-3

Burner dosing valve (DV2); short circuit to ground

63

523911

11

7-2-3

Burner dosing valve (DV2); short circuit high side powerstage