Installation, 4 nema 4x (ip65) models with disconnect switch – Lenze ESV SMV frequency inverter User Manual

Page 17

Advertising
background image

Lenze SMVector 13465100 EDBSV01 EN v18

15

Installation

3.1.4

NEMA 4X (IP65) Models with Disconnect Switch

b2

b

b1

a

a1

c

c1

s1

s2

s2

s1

Mounting Screws

4 x #8-32

10 lb-in

4 x M4

1.2 Nm

(

)

Type

a

in

(mm)

a1

in

(mm)

b

in

(mm)

b1

in

(mm)

b2

in

(mm)

c

in

(mm)

c1

in

(mm)

s1

in

(mm)

s2

in

(mm)

m

lb

(kg)

AA1

ESV371N01SM_; ESV371N02YM_;
ESV371N02SL_; ESV371N04TM_;
ESV371N04TL_; ESV371N06TM_;
ESV751N01SM_; ESV751N02YM_;
ESV751N02SL_; ESV751N04TM_;
ESV751N04TL_; ESV751N06TM_;

6.28

(160)

5.90

(150)

10.99

(279)

9.54

(242)

0.66

(17)

4.47

(114)

.86

(22)

2.00

(51)

2.00

(51)

4.7

(2.13)

AA2

ESV112N01SM_; ESV112N02YM_;
ESV112N02SL_; ESV112N04TM_;
ESV112N04TL_; ESV152N02YM_;
ESV152N02SL_; ESV152N04TM_;
ESV152N04TL_; ESV152N06TM_;
ESV222N04TM_; ESV222N04TL_;
ESV222N06TM_; ESV302N04TL_;

6.28

(160)

5.90

(150)

10.99

(279)

9.54

(242)

0.66

(17)

6.31

(160)

.86

(22)

2.00

(51)

2.00

(51)

7.9

(3.58)

AD1 ESV222N02SL_; ESV222N02YM_;

7.12

(181)

6.74

(171)

10.99

(279)

9.54

(242)

0.66

(17)

6.77

(172)

.86

(22)

2.00

(51)

2.00

(51)

9.0

(4.08)

AB1

ESV552N02TM~; ESV752N02TM~
ESV752N04TM~; ESV752N06TM~;
ESV752N04TL~

8.04

(204)

7.56

(192)

13.00

(330)

11.04

(280)

0.92

(23)

8.00

(203)

.86

(22)

4.00

(102)

4.00

(102)

13.9

(6.32)

AC1

ESV402N02TM_; ESV402N04TM_;
ESV552N04TM_; ESV402N06TM_;
ESV552N06TM_; ESV402N04TL_;
ESV552N04TL_

8.96

(228)

8.48

(215)

13.00

(330)

11.04

(280)

0.92

(23)

8.04
204)

.86

(22)

4.00

(102)

4.00

(102)

14.7

(6.66)

AE1

ESV113N04TM~; ESV153N04TM~,
ESV113N06TM~; ESV153N06TM~

9.42

(240)

8.94

(228)

14.50

(368)

12.54

(319)

0.92

(24)

9.45

(241)

0.73

(19)

4.00

(102)

4.00

(102)

23.0

(10.4)

AF1

ESV113N02TM~; ESV153N02TM~
ESV113N04TL~; ESV153N04TL~
ESV183N04TL~; ESV223N04TL~
ESV183N04TM~; ESV223N04TM~
ESV183N06TM~; ESV223N06TM~

9.42

(240)

8.94

(228)

18.5

(470)

16.54

(420)

0.92

(24)

9.45

(241)

0.73

(19)

4.00

(102)

4.00

(102)

28.5

(12.9)

_ = Last digit of part number:

C = N4X Indoor (convection cooled)

~ = Last digit of part number: D = N4X Indoor (fan cooled)

Conduit Hole Dimensions

Type

N

in (mm)

P

in (mm)

Q

in (mm)

S

in (mm)

S1

in (mm)

Q

Q

P

N

S

S

S1

P

Q

Q

N

AA1

3.14 (80)

2.33 (59)

1.50 (38)

.88 (22)

n/a

AA2

3.14 (80)

4.18 (106)

1.50 (38)

.88 (22)

n/a

AD1

3.56 (90)

4.63 (118)

1.50 (38)

.88 (22)

n/a

AB1

4.02 (102)

5.00 (127)

1.85 (47)

1.06 (27)

n/a

AC1

4.48 (114)

5.00 (127)

1.85 (47)

1.06 (27)

n/a

AE1

4.71 (120)

5.70 (145)

2.00 (51)

1.375 (35)

1.125 (28)

AF1

4.71 (120)

5.70 (145)

2.00 (51)

1.375 (35)

1.125 (28)

Advertising