Fault

Cause

Remedy

(1)

f.OF

Output fault:
Transistor fault

Output short circuit

Check motor/motor cable

Acceleration time too short

Increase P104, P125

Severe motor overload, due to:
• Mechanical problem
• Drive/motor too small for application

• Check machine / system
• Verify drive/motor are proper size for

application

Boost values too high

Decrease P168, P169

Excessive capacitive charging current of
the motor cable

• Use shorter motor cables with lower charging

current

• Use low capacitance motor cables
• Install reactor between motor and drive.

Failed output transistor

Contact factory technical support

f.OF1

Output fault: Ground fault Grounded motor phase

Check motor and motor cable

Excessive capacitive charging current of
the motor cable

Use shorter motor cables with lower charging
current

f.PF

Motor Overload fault

Excessive motor load for too long

• Verify proper setting of P108

• Verify drive and motor are proper size for

application

f.rF

Flying Restart fault

Controller was unable to synchronize with
the motor during restart attempt; (P110
= 5 or 6)

Check motor / load

f.SF

Single-Phase fault

A mains phase has been lost

Check mains voltage

f.UF

Start fault

Start command was present when power
was applied (P110 = 0 or 2).

• Must wait at least 2 seconds after power-up

to apply Start command

• Consider alternate starting method (P110).

f.FAU

TB5 (0-10V signal)
Threshold fault

0-10V signal (at TB5) drops below the value
set in P158.

• Check signal/signal wire
• Refer to parameters P157 and P158

(1)

The drive can only be restarted if the error message has been reset.