Commissioning, 7 diagnostic parameters – Lenze ESV SMV frequency inverter User Manual

Page 46

Advertising
background image

44

Lenze SMVector 13465100 EDBSV01 EN v18

Commissioning

4.5.7

Diagnostic Parameters

Code

Display Range (READ ONLY)

IMPORTANT

No.

Name

p500

Fault History

• Displays the last 8 faults
• Format: n.xxx where: n = 1..8,

1 is the newest fault; xxx = fault message (w/o the F.)

• Refer to section 5.3

P501

Software Version

Format: x.yz

P502

Drive ID

A flashing display indicates that the Drive ID stored in the EPM
does not match the drive model it is plugged into.

P503

Internal Code

Alternating Display: xxx-; -yy

P505

DC Bus Voltage

0

{VDC} 1500

P506

Motor Voltage

0

{VAC} 1000

P507

Load

0 {%} 255

Motor load as % of drive’s output current rating.
Refer to section 2.3.

P508

Motor Current

0.0 {A} 1000

Actual motor current

P509

Torque

0 {%} 500

Torque as % of motor rated torque (vector mode only)

P510

Output Power kW

0.00 {kW} 650.0

P511

Total kWh

0.0

{kWh} 9999999

Alternating display: xxx-; yyyy when value exceeds 9999

P512

Heatsink Temp

0 {°C} 150

Heatsink temperature

P520

0-10 VDC Input

0.0 {VDC} 10.0

Actual value of signal at TB-5 (See P162)

P521

4-20 mA Input

0.0 {mA} 20.0

Actual value of signal at TB-25 (See P162)

P522

TB-5 Feedback

P204

P205

TB-5 signal value scaled to PID feedback units (See P162)

P523

TB-25 Feedback

P204

P205

TB-25 signal value scaled to PID feedback units (See P162)

P524

Network Feedback

P204

P205

Network signal value scaled to PID feedback units

P525

Analog Output

0

{VDC} 10.0

Refer to P150…P155

P527

Actual Output
Frequency

0 {Hz} 500.0

P528

Network Speed
Command

0 {Hz} 500.0

Command speed if (Auto: Network) is selected as the speed
source

P530

Terminal and
Protection Status

Indicates terminal status using segments of the LED display.
(Refer to section 4.5.7.1)

P531

Keypad Status

Indicates keypad button status using segments of the LED
display. (Refer to section 4.5.7.2)

P540

Total Run Time

0

{h} 9999999

Alternating display: xxx-; yyyy when value exceeds 9999

P541

Total Power On Time 0

{h} 9999999

P550

Fault History

1 8

• Displays the last 8 faults
• Format: n.xxx where: n = 1..8,

1 is the newest fault; xxx = fault message (w/o the F.)

• Refer to section 5.3

P551

Fault History Time

0

{h} 999999

Display: “n.hh-” “hhhh” “mm.ss” = fault #, hours, seconds
The “hhhh” screen is displayed after hours exceed 999.

P552

Fault History Counter 0 255

Number of sequential occurrences of a fault.
For example: 3 external faults occur over a period of time
with no other errors occurring. Then P552 will indicate 3,
P550 will indicate the error EF and P551 will indicate the
time of the first fault occurrence.