Commissioning – Lenze ESV SMV frequency inverter User Manual

Page 52

Advertising
background image

50

Lenze SMVector 13465100 EDBSV01 EN v18

Commissioning

Code

Possible Settings

IMPORTANT

No.

Name

Default Selection

Segment #6

P735

Segment #6
Frequency Setpoint

0.0

-500.0 {Hz} 500.0

If P112 = 1, negative sign forces reverse
direction

P736

Segment #6
Accel/Decel Time

20.0

0.0

{sec} 3600.0

P737

Segment #6
Time in current step

0.0

0

0.0

{P708} 6553.5

0

{P708} 65535

Scaling/units depend on P708
Skip segment if time = 0

P738

Segment #6
Digital Output State

0

Value set in P738

0 1 2 3 4 5 6 7

Relay (Bit 0)

0 1 0 1 0 1 0 1

TB14 (Bit 1)

0 0 1 1 0 0 1 1

I/O option Relay (Bit 2)

0 0 0 0 1 1 1 1

NOTE: P441 is the Relay Output (TB-19, 20, 21) of the
optional Digital I/O module (ESVZAL0, ESVZAL1).

bit = 0: OFF (De-energized)
bit = 1: ON (Energized)
The corresponding digital output/relay must be
set to accept data from the sequencer: P140,
P142, P441 = 27

P739

Segment #6 TB30
Analog Output
Value

0.00

0.00

{VDC} 10.00

TB30 configuration parameter must be set to
accept this value: P150 = 10

Segment #7

P740

Segment #7
Frequency Setpoint

0.0

-500.0 {Hz} 500.0

If P112 = 1, negative sign forces reverse
direction

P741

Segment #7
Accel/Decel Time

20.0

0.0

{sec} 3600.0

P742

Segment #7
Time in current step

0.0

0

0.0

{P708} 6553.5

0

{P708} 65535

Scaling/units depend on P708
Skip segment if time = 0

P743

Segment #7
Digital Output State

0

Value set in P743

0 1 2 3 4 5 6 7

Relay (Bit 0)

0 1 0 1 0 1 0 1

TB14 (Bit 1)

0 0 1 1 0 0 1 1

I/O option Relay (Bit 2)

0 0 0 0 1 1 1 1

NOTE: P441 is the Relay Output (TB-19, 20, 21) of the
optional Digital I/O module (ESVZAL0, ESVZAL1).

bit = 0: OFF (De-energized)
bit = 1: ON (Energized)
The corresponding digital output/relay must be
set to accept data from the sequencer: P140,
P142, P441 = 27

P744

Segment #7 TB30
Analog Output
Value

0.00

0.00

{VDC} 10.00

TB30 configuration parameter must be set to
accept this value: P150 = 10

Segment #8

P745

Segment #8
Frequency Setpoint

0.0

-500.0 {Hz} 500.0

If P112 = 1, negative sign forces reverse
direction

P746

Segment #8
Accel/Decel Time

20.0

0.0

{sec} 3600.0

P747

Segment #8
Time in current step

0.0

0

0.0

{P708} 6553.5

0

{P708} 65535

Scaling/units depend on P708
Skip segment if time = 0

P748

Segment #8
Digital Output State

0

Value set in P748

0 1 2 3 4 5 6 7

Relay (Bit 0)

0 1 0 1 0 1 0 1

TB14 (Bit 1)

0 0 1 1 0 0 1 1

I/O option Relay (Bit 2)

0 0 0 0 1 1 1 1

NOTE: P441 is the Relay Output (TB-19, 20, 21) of the
optional Digital I/O module (ESVZAL0, ESVZAL1).

bit = 0: OFF (De-energized)
bit = 1: ON (Energized)
The corresponding digital output/relay must be
set to accept data from the sequencer: P140,
P142, P441 = 27

P749

Segment #8 TB30
Analog Output
Value

0.00

0.00

{VDC} 10.00

TB30 configuration parameter must be set to
accept this value: P150 = 10

Advertising