Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 2.0 - 10/2013

100

Parameter reference

Parameters of the Communication Unit

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13851

C13858

C13861

Parameter | Name:

C13851 | All words from scanner

Data type: INTEGER_16

Index: 10724 = 0x29E4

Display of the I/O data words transferred from the scanner to the Communication Unit (adapter).

In the subcodes, all I/O data words transferred from the scanner are displayed. However, only the configured I/O

data words are valid.
Display range

(min. value | unit | max. value)

-32768

32767

Subcodes

Info

C13851/1
...
C13851/8

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13858 | Ethernet Port Statistics

Data type: UNSIGNED_32

Index: 10717 = 0x29DD

Display of statistical values for the data transfer via the Ethernet connections
Subcodes

Info

C13858/1

Ethernet port X31: RX

C13858/2

Ethernet port X31: RX CRC error

C13858/3

Ethernet port X31: RX discarded

C13858/4

Ethernet port X31: TX

C13858/5

Ethernet port X31: TX discarded

C13858/6

Ethernet port X32: RX

C13858/7

Ethernet port X32: RX CRC error

C13858/8

Ethernet port X32: RX discarded

C13858/9

Ethernet port X32: TX

C13858/10

Ethernet port X32: TX discarded

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13861 | CIP Module Status

Data type: UNSIGNED_16

Index: 10714 = 0x29DA

Display of the current CIP module status

(Instance attribute 8 (State) in the

Identity Object (1 / 0x01) ( 110)

)

• The status is also indicated via the MS LED.

LED status displays ( 78)

Selection list

(read only)

0 Nonexistent
1 Device Self Testing
2 Standby
3 Operational
4 Major Recoverable Fault
5 Major Unrecoverable Fault

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT