Commissioning – Lenze E84DGFCG User Manual

Page 32

Advertising
background image

Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 2.0 - 10/2013

32

Commissioning

Setting the IP configuration of the Inverter Drive 8400 motec

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2. A double-click on a EtherNet/IP node opens the "Configure nodes" dialog window.

Here you can set the IP parameters.

3. Click on Transferred.

• The IP configuration is transferred to the corresponding EtherNet/IP node.
• The Communication Unit executes a stack reset.
• The IP parameters are written to codes

C13000

(IP address),

C13001

(subnet mask), and

C13002

(gateway address).

• Code

C13005

(IP configuration reference) is set to ’0: Saved address’ to ensure that the

transferred address can be used.

Tip!
Check whether the configuration has been transferred successfully.
For this purpose, open the "Assign IP addresses" dialog window (see step 1) and click the

Find device button.