Error messages

Possible causes and remedies

85

Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 2.0 - 10/2013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

EtherNet/IP: Idle Mode [0x01bc8132] (nt05: COM fault 5)

EtherNet/IP: Duplicate IP Address [0x01bc8273]

Response (Lenze setting printed in bold)

Setting:

C13880/1

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

• Scanner has received an idle event.

• The scanner is in the "PROG" mode.

• In the "Scanner Command Register", the run/

idle flag (bit 0) is 0.

Set the scanner to the run mode.

Run/idle flag (bit 0) = 1

Response (Lenze setting printed in bold)

Setting: not possible

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

An IP address has been allocated twice within the

network. The addresses of the network nodes must differ

from each other.

Correct the IP address (

C13000

).

Setting the IP configuration of the Inverter Drive 8400

motec ( 30)