4 technical data, 1 general data and operating conditions, Technical data – Lenze E84DGFCG User Manual

Page 17: General data and operating conditions, 4technical data

Advertising
background image

Technical data

General data and operating conditions

17

Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 2.0 - 10/2013

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4

Technical data

4.1

General data and operating conditions

Hardware manual for Inverter Drives 8400 motec
Here you will find the ambient conditions and information on the electromagnetic

compatibility (EMC) that also apply to the Communication Unit.

Range

Values

Order designation

• E84DGFCGxNx (EtherNet/IP)

• E84DGFCGxJx (EtherNet/IP + Safety)

Communication profile

EtherNet/IP

Standards / specifications

Safety engineering: EN 954-1, EN 13849-1, IEC 61508

(up to safety category 4)

Interface for communication

• EtherNet/IP port 1: M12 socket, 5-pin, D-coded

• EtherNet/IP port 2: M12 socket, 5-pin, D-coded

Network topology

Tree, star, and line

Type of node

Adapter (slave)

Number of nodes

Max. 254 in the subnetwork

Max. cable length

100 m

Vendor ID

587 (0x24B), Lenze (’Lenze AC Tech’ in older Rockwell data)

Device type

2 (0x02), AC Drive

Product code

8440 (0x20F8)

Baud rate

• 10 Mbps

• 100 Mbps

Transmission mode

Half duplex / full duplex

Switching method

Store-and-forward / cut-through

Switch latency

Approx. 125 μs at max. telegram length

External voltage supply

• U = 24 V DC (20 V - 0 % ... 29 V + 0 %)

• I

max

= 400 mA

Conformities, approvals

• CE

• UR / cUR

(see also hardware manual)