Ethernet/ip: invalid ip, Parameters [0x01bc6533, 0x01bc6430 – Lenze E84DGFCG User Manual

Page 84: 0x01bc6533, 0x01bc8111, 0x01bc8112, 0x01bc8114, Error messages

Advertising
background image

Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 2.0 - 10/2013

84

Error messages

Possible causes and remedies

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

EtherNet/IP: Invalid Configuration [0x01bc6430]

EtherNet/IP: Invalid IP Parameters [0x01bc6533]

EtherNet/IP: Fault Mode [0x01bc8111]

EtherNet/IP: Explicit Message Timeout [0x01bc8112]

EtherNet/IP: Overall Ethernet Timeout [0x01bc8114]

Response (Lenze setting printed in bold)

Setting: not possible

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Module configuration is faulty.

Check and correct module configuration.

Response (Lenze setting printed in bold)

Setting: not possible

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

One or more IP parameters are faulty.

Check and correct IP configuration.

Setting the IP configuration of the Inverter Drive 8400

motec ( 30)

Response (Lenze setting printed in bold)

Setting:

C13880/2

No reaction  System fault  Fault  Trouble  TroubleQuickStop  WarningLocked  Warning  Information

Cause

Remedy

• Connection to scanner has been interrupted.

• Controlling I/O connection failed by timeout.

• Within the timeout time for implicit messages

parameterised by the scanner, no "implicit messages"

have been received.

• Check cables and terminals.

• Plug the network cable into the EtherNet/IP terminal.

• Check Requested Package Interval (RPI) of I/O

connection.

• Increase timeout time for implicit messages.

Response (Lenze setting printed in bold)

Setting:

C13880/3

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

• Connection to scanner has been interrupted.

• Failure of an explicit connection

• Within the timeout time for explicit messages

parameterised by the scanner, no "explicit messages"

have been received.

• Check cables and terminals.

• Plug the network cable into the EtherNet/IP terminal.

• Check Requested Package Interval (RPI) of the explicit

connection.

• Increase timeout time for explicit messages.

Response (Lenze setting printed in bold)

Setting:

C13880/4

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

• Failure of »Engineer« communication via Ethernet

• When the time set in

C13881

has expired, there is no

access via the »Engineer«.

• Check cables and terminals.

• Plug in network cable.

• Increase the overall Ethernet timeout time in

C13881

.

Fault with regard to EtherNet/IP communication

( 77)

Advertising