4 technical data, Technical data, 4technical data – Lenze E84Dxxxx User Manual

Page 13

Advertising
background image

Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17

13

4

Technical data

4.1

General data and operating conditions of the EtherNet/IP

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4

Technical data

4.1

General data and operating conditions of the EtherNet/IP

Mounting instructions/hardware manual for Inverter Drives 8400 protec
Here you can find information on general technical data, operating conditions, and rated

data of the device.

Range

Values

Communication profile

EtherNet/IP

Communication medium

S/FTP (Screened Foiled Twisted Pair, ISO/IEC 11801 or EN 50173), CAT 5e

Interface for communication

RJ45 Standard Ethernet (in accordance with IEEE 802.3), 100Base-TX (Fast

Ethernet) or M124-socket (4-pole, D-coded)

Network topology

Tree, star, and line

Type of node

Adapter (slave)

Number of nodes

Max. 254 in the subnetwork

Max. cable length

100 m

Vendor ID

587 (0x24B), Lenze (’Lenze AC Tech’ in older Rockwell data)

Device type

2 (0x02), AC Drive

Product code

8410 (0x20DA)

Baud rate

• 10 Mbps

• 100 Mbps

Transmission mode

Half duplex / full duplex

Switching method

Store-and-forward / cut-through

Switch latency

Approx. 125 μs at max. telegram length