14

Implemented CIP™ objects

14.2

EtherNet/IP objects

130

Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Instance attribute "Control Bits" (attribute 6, Interface Control)

Supported service codes

Bits

Name

Description

0

Auto-negotiate

Activation of "Link Auto-Negotiation"

• 0: "Link Auto-Negotiation" is inactive.

• The device uses the settings of the bits "Forced Duplex Mode"

(bit 1) and "Forced Interface Speed" (see attribute 6, Interface

Control).

• 1: "Link Auto-Negotiation" is active.

1

Forced Duplex Mode

If "Auto-negotiate" bit = 0, this bit indicates the transmission mode to be

used.

• 0: Half duplex

• 1: Full duplex

2 ... 15

-

Reserved (0)

Service code

[hex]

Name

Description

0x01

Get_Attributes_All

Outputs a list of the attributes and the attribute's values for

a certain object.

0x0E

Get_Attribute_Single

Outputs the value of a certain attribute.

0x10

Set_Attribute_Single

Changes the value of a certain attribute.