4 i/o configuration in the »engineer, I/o configuration in the »engineer, 8i/o data transfer (implicit messages) – Lenze E84Dxxxx User Manual
Page 48
8
I/O data transfer (implicit messages)
8.4
I/O configuration in the »Engineer«
48
Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.4
I/O configuration in the »Engineer«
Lenze technology application / configuring user-definable parameter sets
How to configure the Lenze technology applications / user-definable parameter sets in the
»Engineer«:
1. Select or change the application (C00005) in the Application parameter tab.
In the example, the "speed actuating drive" application (C00005 = 1000) is configured.
•
Click the application button:
switch-off positioning
speed actuating drive
table positioning
•
Select the application in the "Insert application" dialog box.
2. Make the default setting of the I/O configuration.
Select "MCI" control mode (C00007 = 40).