Commissioning

6.4

Establishing an online connection via EtherNet/IP with the Lenze »Engineer«

36

Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

In the »Engineer«, you can use the Online Set communication path and go online menu

command to select the EtherNet/IP communication path. The previously configured EtherNet/IP

nodes are shown in the "Communication path" dialog window:

If the device access path is not configured correctly, here the

IP address of the inverter selected

in the display field can be entered manually.

Via the

Search/Enter button, you can establish a connection to devices which have not

appeared in the display field. Corresponding settings for this can be made in the "Enter IP Address"

dialog window that will appear:

Here you can enter an

IP address manually or execute the following actions using the buttons:

• Execute the console command

Ping.

• Assign the IP address via the

Configurator.

Setting via the EtherNet/IP configurator of the »Engineer«

( 29)

• Select the device access path to the desired inverter by clicking

Find.

After having established the online connection, you can continue work with the »Engineer« as

usual.