14

Implemented CIP™ objects

14.3

"AC Drive Profile" objects

132

Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

14.3.1

Motor Data Object (40 / 0x28)

The "Motor Data Object" provides a data basis for motor parameters.

Class attributes

Instance attributes

Instance attributes for AC motor types

For a write access to the attributes "RatedCurrent" and "RatedVoltage", the controller enable

(RFR = 0) must be deactivated.

Supported service codes

Attribute

ID

Service

Name

Data type

Value

1

Get

Revision

UINT

1 (0x0001)

2

Get

Max. Instance

UINT

1 (0x0001)

3

Get

Number of Instances

UINT

1 (0x0001)

Attribute

ID

Service

Name

Data type

Value

1

Get

NumAttr

USINT

Number of supported attributes

2

Get

Attributes

ARRAY of

USINT

Listing of the supported attributes

3

Get / Set MotorType

USINT

AC motor type

• 6: Wound-rotor induction motor

• 7: Squirrel-cage induction motor

Attribute

ID

Service

Name

Data type

Value

6

Get / Set RatedCurrent

UINT

Rated stator current [100mA]

7

Get / Set RatedVoltage

UINT

Rated base voltage [V]

Service code

[hex]

Name

Description

0x01

Get_Attributes_All

Outputs a list of the attributes and the attribute's values for

a certain object.

0x0E

Get_Attribute_Single

Outputs the value of a certain attribute.

0x10

Set_Attribute_Single

Changes the value of a certain attribute.