19

5

Installation

5.2

EtherNet/IP connection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2.1

EtherNet/IP connection via the RJ45 socket

A standard Ethernet patch cable is suitable for connecting the Inverter Drive 8400 protec to the

EtherNet/IP fieldbus.

Ethernet cable specification

( 20)

The installation and removal of the Ethernet cables is optimised for the use of connectors in

accordance with the "Automation Initiative of German Domestic Automobile Manufacturers"

(AIDA).

5.2.1.1

Pin assignment

Tip!
The EtherNet/IP interfaces feature an auto MDIX function. This function adjusts the

polarity of the RJ45 interfaces so that a connection is established irrespective of the polarity

of the opposite EtherNet/IP interface, and irrespective of the cable type used (standard

patch cable or crossover cable).

Note!

To prevent the RJ45 socket from being damaged, insert or remove the Ethernet cable

connector straight (at a right angle) into or from the socket.

RJ45 socket

Pin

Signal

E94AYCXX004C

1

Tx +

2

Tx -

3

Rx +

4

-

5

-

6

Rx -

7

-

8

-

Note!

Dependent on the configuration of the Ethernet port of the device to be connected, we

recommend the use of a cross-over cable.