13

Parameter reference

13.1

Parameters relevant for communication

88

Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13

Parameter reference

This chapter supplements the parameter list and the table of attributes in the reference manual and

the »Engineer« online help for the Inverter Drives 8400 protec by the EtherNet/IP parameters.

13.1

Parameters relevant for communication

This chapter lists the EtherNet/IP parameters in numerically ascending order.

C13000

C13001

Reference manual / »Engineer« online help for Inverter Drives 8400 protec
Here you will find general information on parameters.

Parameter | Name:

C13000 | IP Address

Data type: UNSIGNED_8

Index: 11575

d

= 2D37

h

Setting of the IP address

Setting the IP configuration of the Inverter Drive 8400 protec ( 28)

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C13000/1

192

IP address (most significant byte)

C13000/2

168

IP address

C13000/3

124

IP address

C13000/4

16

IP address (least significant byte)

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13001 | Subnetwork Mask

Data type: UNSIGNED_8

Index: 11574

d

= 2D36

h

Setting of the subnet mask

Setting the IP configuration of the Inverter Drive 8400 protec ( 28)

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C13001/1

255

Subnet mask (most significant byte)

C13001/2

255

Subnet mask

C13001/3

255

Subnet mask

C13001/4

0

Subnet mask (least significant byte)

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT