C13848 | last conflicted mac id, C13849 | last conflicted ip address, C13850 | all words to scanner – Lenze E84Dxxxx User Manual

Page 96: C13850, 13 parameter reference

Advertising
background image

13

Parameter reference

13.1

Parameters relevant for communication

96

Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13848

C13849

C13850

Parameter | Name:

C13848 | Last Conflicted MAC ID

Data type: OCTET_STRING

Index: 10727

d

= 29E7

h

Display of the MAC address of the EtherNet/IP node with the last address conflict (ACD).

The data of the last conflict will only be saved in this code if ACD is active at the moment when the conflict occurs

(

C13846

= 1).

(Instance attribute 11 (RemoteMAC) in the

TCP/IP Interface Object (245 / 0xF5) ( 124)

)

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13849 | Last Conflicted IP Address

Data type: UNSIGNED_8

Index: 10726

d

= 29E6

h

Display of the MAC address of the EtherNet/IP node with the last address conflict (ACD).

The data of the last conflict will only be saved in this code if ACD is active at the moment when the conflict occurs

(

C13846

= 1).

Display range

(min. value | unit | max. value)

0

255

Subcodes

Info

C13849/1

Last conflicted IP address (most significant byte)

C13849/2

Last conflicted IP address

C13849/3

Last conflicted IP address

C13849/4

Last conflicted IP address (least significant byte)

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13850 | All words to scanner

Data type: INTEGER_16

Index: 10725

d

= 29E5

h

Indication of the I/O data words that are transferred from the Inverter Drive 8400 protec (adapter) to the scanner.

In the subcodes, all I/O data words transferred to the scanner are displayed. However, only the configured I/O data

words are valid.
Display range

(min. value | unit | max. value)

-32768

32767

Subcodes

Info

C13850/1
...
C13850/16

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT