C13002 | gateway address, C13003 | mac id, C13005 | ip config control – Lenze E84Dxxxx User Manual

Page 89: C13002, C13005, Code, C13003, 13 parameter reference

Advertising
background image

Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17

89

13

Parameter reference

13.1

Parameters relevant for communication

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13002

C13003

C13005

Parameter | Name:

C13002 | Gateway Address

Data type: UNSIGNED_8

Index: 11573

d

= 2D35

h

Setting of the gateway address

Setting the IP configuration of the Inverter Drive 8400 protec ( 28)

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C13002/1

0

Gateway address (most significant byte)

C13002/2

0

Gateway address

C13002/3

0

Gateway address

C13002/4

0

Gateway address (least significant byte)

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13003 | MAC ID

Data type: OCTET_STRING

Index: 11572

d

= 2D34

h

Display of the MAC-ID

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13005 | IP Config Control

Data type: UNSIGNED_8

Index: 11570

d

= 2D32

h

Selection how the IP configuration is to be effected.

(Instance attribute 3 (Configuration Control) in the

TCP/IP Interface Object (245 / 0xF5) ( 124)

)

Setting the IP configuration of the Inverter Drive 8400 protec ( 28)

Selection list

(Lenze setting printed in bold)

Info

0 Use stored IP

The IP configuration currently stored in the Inverter Drive

8400 protec is used.

1 Use BOOTP

The IP configuration is assigned by the scanner using

BOOTP.

2 Use DHCP

The IP configuration is assigned by the scanner using

DHCP.

The assignment of a gateway address which is not in the

same subnetwork than the IP address, is rejected.

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising