C13844 | beacon times, C13845 | beacon frames, C13846 | address conflict detection – Lenze E84Dxxxx User Manual

Page 95: C13847 | active conflict detection state, 13 parameter reference

Advertising
background image

Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17

95

13

Parameter reference

13.1

Parameters relevant for communication

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13844

C13845

C13846

C13847

Parameter | Name:

C13844 | Beacon Times

Data type: UNSIGNED_32

Index: 10731

d

= 29EB

h

Display of the beacon times (μs)
Subcodes

Info

C13844/1

Beacon interval

C13844/2

Beacon timeout

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13845 | Beacon Frames

Data type: UNSIGNED_32

Index: 10730

d

= 29EA

h

Display of beacon frame information
Subcodes

Info

C13845/1

Beacon frames - port X31

C13845/2

Beacon frame error - port X31

C13845/3

Beacon frames - port X32

C13845/4

Beacon frame error - port X32

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13846 | Address Conflict Detection

Data type: UNSIGNED_8

Index: 10729

d

= 29E9

h

Activation of the address conflict detection (ACD)

(Instance attribute 10 (SelectAcd) in the

TCP/IP Interface Object (245 / 0xF5) ( 124)

)

Changing this value requires a reset of the device ("power off/on" or "type 0 reset").
Selection list

(Lenze setting printed in bold)

0 Deactivated
1 Enable

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13847 | Active Conflict Detection State

Data type: UNSIGNED_8

Index: 10728

d

= 29E8

h

Display of the status of address conflict detection (ACD)
Selection list

(read only)

0 Not conflicted
1 Conflicted

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising