Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17

43

8

I/O data transfer (implicit messages)

8.1

I/O data mapping

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.1

I/O data mapping

I/O data transfer takes place via the MCI interface.

• Access to the I/O data takes place via port blocks LP_MciIn and LP_MciOut.
• The LP_MciIn port block maps the received data objects.
• The LP_MciOut port block maps the data objects to be sent.
• Up to 16 data words (32 bytes) per direction can be exchanged.
• The ports/function blocks of the I/O data objects are interconnected with the Lenze »Engineer«.

[8-1]

Outer and inner data transfer between bus system, inverter, and application

Reference manual / online help for Inverter Drives 8400 protec
Here you will find detailed information on the port/function block interconnection in

the »Engineer« and on the port blocks.