Unwinding from above or from below, 9 setting of the pid controller – Lenze 8615E User Manual

Page 115

Advertising
background image

9.8.2 Winding or unwinding

Winding from above or from below

The command “unwinding from above” or “unwinding from below”

is given by the

reversal (reversing command e.g. via

terminals 21 and 22).

Unwinding from above or from below

For unwinding, the sign for the influence of the dancer-Position

Controller must be

This achieved by the following:

l

Change the polarity of the voltage supply for the dancer
Potentiometer.

l

Invert the act. dancer

at the analog input

l

Invert the gain

for the actuat-value

Invert the dancer-Position

at the same time.

The command “unwinding from above” or “unwinding from below”

is given by the

reversal (reversing command e.g. via

terminals 21 and 22).

9.9

Setting of the PID controller

l

The PID controller

only be set

Operation (with

material).

C o d e N a m e

Parameter (Factory setting printed in

Acceptance

Dancer-

1

0 . 1

100 ON-LINE

controller

component Vp

Dancer-

9 9 9 9 m s

20 ms

(10 ms)

ms ON-LINE

controller

INFO: 9999 ms =

reset

c o m p o n e n t T n

Dancer-

SH + PRG

I-component reset

controller reset

Cl

Dancer-

0 . 0

0 . 0

IO.11

5.0 ON-LINE

controller

component kd

Dancer-

D-component actlve

SH + PRG

D-component reset

controller reset

D-component

The 1-component and the D-component

be reset via a freely

assignable terminal, via the keypad or via the serial

113