3application-specific controller, 1 applications with extreme overload, peak torque – Lenze 8615E User Manual
Page 21
Advertising
3
Application-specific controller
3.1
Applications with extreme overload,
peak torque
up
to 230% of the rated motor torque
For applications where a very extreme
and
overload torque are necessary (e.g. presses,
machines).
The controller provides 200% of the rated torque for
a maximum of 30s.
With cyclic overload, the ratio between overload to
cycle time must not exceed 0.2.
For these applications, the monitoring of the output
is set to Operation with rated power
using the
Cl 19 and Cl20 (see page 82)
(factory setting)
Please note that a maximum ambient temperature of
50°C is permissible.
55.0
110.0
220.0
76.2
91.4
96.0
1270