Application-specific controller

3.1

Applications with extreme overload,

peak torque

up

to 230% of the rated motor torque

For applications where a very extreme

and

overload torque are necessary (e.g. presses,
machines).

The controller provides 200% of the rated torque for

a maximum of 30s.

With cyclic overload, the ratio between overload to
cycle time must not exceed 0.2.

For these applications, the monitoring of the output

is set to Operation with rated power

using the

Cl 19 and Cl20 (see page 82)

(factory setting)

Please note that a maximum ambient temperature of

50°C is permissible.

55.0

110.0

220.0

76.2

91.4

96.0

1270