To activate the

compensator the threshold which is to be

set

C94

must

be decreased so that the dancer-Position

controller

be activated. With the setting of Cl 94 = 100 %

(factory setting) the

compensator is disconnected from

the dancer-Position controller.

9.10.1 Reset of the

compensator

The

compensator

be reset (e.g. after finishing the

winding process) via a freely assignable digital input, the operating
unit, or the LECOM

Select the freely assignable terminal which is to be assigned to the

function “diameter compensator reset” via

Cl 12. This function

is assigned to the freely assignable terminal

Cl 13. If

the

compensator is enabled via the freely assignable

terminal, the thresholds will be compared first. When activating the
“diameter compensator reset”, the counter value is set to
After

mains connection, the

compensator is set to

Caution!

If the controller is enabled when the

compensator is reset,

then the counter value is set to zero immediately. Thus, with a high

compensator

when activating the “diameter

compensator reset” the

value which is

of the

abruptly and as a result the field frequency is also

This may lead to high accelerations and the

limiting function

may be activated.

The integration time

be set

Cl 95 (unit [s]), and the

decrement time

be determined

Cl96 (unit

If the output of the dancer-Position controller falls below the

threshold set

Cl 94 after the

compensator has

already been activated, the correction value of the
compensator will not be

as long as

l

the

compensator is reset via a freely assignable

terminal or

l

the supply voltage of the frequency controller is switched off

(e.g. the controller is not connected to the mains) or

l

the

compensator has to be activated again

the output of the dancer-Position controller exceeds the
threshold set

Cl 94.

The function Cl 94 is not reset by controller inhibit.

The threshold set

Cl 94 refers to 100% of the modulation of

the dancer-Position controller.

INFO: 100 % = Diameter compensator swtiched off.