2warning, 3monitoring – Lenze 8615E User Manual

Page 152

Advertising
background image

2

Warning

A warning is displayed automatically

C067.

a warning

the

“ready” is removed, however, the Operation of the

frequency controller is not interrupted.

Reset of the warning:

Press SH + PRG
or

List of warnings

Display on Display on Fault

Cause

keypad

h o s t

2 0 3

Overheat PTC Motor is overheated

i n p u t

P T C c o n n e c t i n g c a b l e
i n t e r r u p t e d

Remedy

Check dimensioning of the drive
Check PTC connection

2 4 1

P T C i n p u t o p e n

E x t e r n a l f a u l t

S i g n a l v i a d i g i t a l i n p u t “ f a u l t

Check external act. value

i n d i c a t i o n ”
Incorrect programming of the

i n p u t “ f a u l t i n d i c a t i o n ”

Check programming of the input

“ f a u l t i n d i c a t i o n ”

3

Monitoring

A monitoring indication

a pulse inhibit and is displayed on

the keypad.The keys are out of

Pulse inhibit is automatically

reset when the DC bus voltage has reached again its permissible

List of monitoring indications

Display on Fault

keypad

L U

L o w v o l t a g e

o u

Overvoltage

Cause

Mains voltage is too low

M a i n s v o l t a g e i s t o o h i g h

Creeping

fault on the motor

side

Remedy

Check mains voltage

Check mains voltage

Increase deceleration times,
when using a brake
check dimensioning and
connection of the brake
increase deceleration times
Check motor cable and motor for

fault (disconnect motor and

c o n t r o l l e r )

150