1.

the above conditions do not apply, you

determine the

suitable brake resistor as follows:

Determine the resistance:

Resistance

required brake peak power

Depending on the unit the resistances must not fall below the

Depending on the unit the resistances must not fall below the
following values:

following values:

Controller type

Controller type

Min. resistancet

Min. resistancet

Controller type
Min. resistance

18612

18615

2.

Determine the rated power of the brake resistor:

1

Cycle time

Resistance

The permissible continuous power of the internal brake
does not

the unit. lt corresponds to the max. permissible

brake power.

3. Determine the thermal capacitance of the resistor:

Thermal capacitance

Resistance

max. brake time

40

Advertising
This manual is related to the following products: