Setting of the controller parameters – Lenze 8615E User Manual

Page 81

Advertising
background image

--.

l

Calculate the required act. value gain according to the following
equation:

Required gain =

measured

desired

l

Enter the calculated value after selecting the suitable act. value

input (C025)

C027.

Setting of the controller Parameters

With the setting of the Controller Parameters, you adapt the Pl
Controller to the drive. This adjustment is

after the

adjustment as well as after the manual adjustment. Proceed as

follows:

l

Increase the gain of the Pl controller

CO70 until the

to oscillate.

l

Then reduce this value by 10%.

l

If there should be no

with a gain of 10, reduce the

adjustment time

until the drive stark to oscillate.

l

Then reduce the gain by 10%.

l

If

already oscillates with the factory setting, increase

the adjustment time, until the drive runs smoothly.

C o d e N a m e

Parameter

setting is printed in bold)

Acceptance

C O 7 0

G a i n o f

1 .oo

0.01

(0.01)

1

ON-LINE

P I c o n t r o l l e r

1

1 0 . 0

1 0

3 0 0

0.10 s

0.01 s

( 0 . 0 1 )

1

s ON-LINE

t i m e o f

1 . 0 s

10.0s

Pl

1 0 s

100s

79