Rated data

Operation with rated power (normal operation)

3

l

117

EDK82EV903 DE/EN/FR 5.1

Ambient conditions

Motor connection

Length of the motor cable

< 50 m

shielded

< 100 m

unshielded

For rated mains voltage and switching frequency

£ 8 kHz

without additional output filters.
For compliance with EMC regulations, the permissible cable
length may be different.

Mechanical

Vibration resistance
(9.81 m/s

2

= 1 g)

Germanischer Lloyd
5 ... 13.2 Hz

Amplitude ±1 mm 13.2 ... 100 Hz:
acceleration resistant up to 0.7 g

IEC/EN 60068−2−6
10 ... 57 Hz

Amplitude 0.075 mm 57 ... 150 Hz:
acceleration resistant up to 1 g

Mounting conditions

Mounting place

In the control cabinet

Mounting position

Vertical

Dimensions,
free spaces

^ Chapter "Mechanical installation"

Weights

^ Chapter "Technical data", "Operation at rated power" or
"Operation at increased rated power"

3.2

Rated data

3.2.1

Operation with rated power (normal operation)

Data for operation at rated mains voltage and switching frequency 8 kHz. Data and
restrictions for other switching frequencies see system manual.

Type

Power

Rated mains voltage

Mains current [A]

Output current [A] )

Mass [kg]

[kW]

without

with

I

r

I

max

(60 s)

1)

without

with

P

r

Mains choke/mains

filter

Mains filter

E82xV153K4B

2)

15

3/PE AC 400 V:

320 V −0 % ... 440 V +0 %
45 Hz −0 % ... 65 Hz +0 %

DC 565 V:

450 V −0 % ... 620 V +0 %

43.5

29

32

48

13.5

(E82CV... 13)

34

3)

E82xV223K4B

2)

22

42

47

70.5

15

(E82CV... 13)

E82xV303K4B

2)

30

55

59

89

15

34

E82xV453K4B

2)

45

80

89

134

36

60

E82xV553K4B

2)

55

100

110

165

38

66

E82xV753K4B

2)

75

135

150

225

59

112

E82xV903K4B

2)

90

165

171

221

59

112

E82xV153K4B

2)

15

3/PE AC 500 V:

400 V −0 % ... 550 V +0 %
45 Hz −0 % ... 65 Hz +0 %

DC 710 V:

565 V −0 % ... 775 V +0 %

43.5

29

32

48

13.5

(E82CV... 13)

34

3)

E82xV223K4B

2)

22

42

47

70.5

15

(E82CV... 13)

E82xV303K4B

2)

30

55

56

84

15

34

E82xV453K4B

2)

45

80

84

126

36

60

E82xV553K4B

2)

55

100

105

157

38

66

E82xV753K4B

2)

75

135

142

213

59

112

E82xV903K4B

2)

90

165

162

211

59

112

1)

Currents for periodic load change: 1 min overcurrent time with I

max

and 2 min base load time with 75 % I

r

2)

Operation only permitted with mains choke (

^ 143

)

3)

E82CV...: Mains filter separately