l

99

EDK82EV903 DE/EN/FR 5.1

E82EV753K4B ... E82EV903K4B

(fold−out page on the right)

Scope of supply and connections

Position

Description

0

8200 vector frequency inverter

1

Fixing bracket for standard mounting

^ 135

2

Blanking covers (2 pieces) for interfaces FIF I and FIF II

^ 162

3

EMC shield sheet with fixing screws for shielded control cables

^ 142

4

Cover with fixing screws

5

Shield clamp and strain relief for the motor cable

^ 154

6

Strain relief for the protective earth cable of the motor and the incoming cable of the motor tempera-
ture monitoring with PTC thermistor (PTC) or thermal contact (NC contact)

7

Label (required for mounting in accordance with UL)

^ 119

T1, T2

PTC connection or thermal contact (NC contact) of the motor

^ 154

U, V, W, PE

Motor connection

^ 154

L1, L2, L3, PE Mains connection

^ 151

+U

G

, −U

G

DC supply

X1.2

Terminal strip for connection of relay output K1

^ 155

X1.3

Terminal strip for connection of relay output K2

X3.1

Terminal strip for connection of relay output K

SR

for "safe standstill" (only for variant Bx4x)

^ 157