Commissioning, Important codes for quick commissioning – Lenze E82EV 8200 vector 15kW-90kW User Manual

Page 180

Advertising
background image

Commissioning

Important codes for quick commissioning

7

l

180

EDK82EV903 DE/EN/FR 5.1

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0010

uSEr

Minimum
output
frequency

0.00

0.00

à

14.5 Hz

{0.02 Hz}

650.00

l

C0010 not effective in the case of
bipolar setpoint selection (−10 V ...
+ 10 V)

l

C0010 only limits the analog input
1

l

In the case of a max. output
frequency > 50 Hz the switching
threshold of the auto DCB in C0019
has to be increased.

l

From software 3.5: If
C0010 > C0011, the drive does not
start when controller enable is set.

à

Speed setting range 1 : 6 for Lenze
geared motors: For operation with
Lenze geared motors has to be set
necessarily.

C0011

uSEr

Maximum
output
frequency

50.00 7.50

à

87 Hz

{0.02 Hz}

650.00

C0012

uSEr

Acceleration
time main
setpoint

5.00

0.00

{0.02 s}

1300.00 Reference: frequency change 0 Hz ...

C0011

l

Additional setpoint

ðC0220

l

Acceleration times that can be
activated via digital signals

ð

C0101

C0013

uSEr

Deceleration
time main
setpoint

5.00

0.00

{0.02 s}

1300.00 Reference: frequency change C0011...

0 Hz

l

Additional setpoint

ðC0221

l

Deceleration times that can be
activated via digital signals

ð

C0103

C0014

v

Operating mode

2

2

V/f characteristic control V ~ f
(linear characteristic with constant V

min

boost)

l

Commissioning is possible without
identifying motor parameters

l

Advantage of identification with
C0148:
– Improved smooth running at low

speeds

– V/f rated frequency (C0015) and

slip (C0021) are calculated and
saved. They do not have to be
entered

3

V/f characteristic control V ~ f

2

(square−law characteristic with constant
V

min

boost)

4

Vector control

In the case of the first selection enter
the motor data and identify them
with C0148
Otherwise commissioning is not
possible
When C0014 = 5, C0019 must be set =
0 (automatic DC injection brake is
deactivated)

5

Sensorless torque control with speed
limitation

l

Torque setpoint via C0412/6

l

Speed limitation via setpoint 1
(NSET1−N1) if C0412/1 is assigned,
otherwise via maximum frequency
(C0011)

C0015

uSEr

V/f rated
frequency

50.00 7.50

{0.02 Hz}

960.00

l

C0015 is calculated and saved
during the motor parameter
identification with C0148.

l

The setting applies to all permitted
mains voltages

C0016

uSEr

V

min

boost

а

0.00

{0.01 %}

40.00

а

device−dependent

Setting applies to all permitted mains
voltages