Standard devices with a power of 45 kw, Mounting with fixing brackets (standard), Mechanical installation – Lenze E82EV 8200 vector 15kW-90kW User Manual
Page 125
![background image](/manuals/565990/125/background.png)
Mechanical installation
Standard devices with a power of 45 kW
Mounting with fixing brackets (standard)
l
125
EDK82EV903 DE/EN/FR 5.1
4.3
Standard devices with a power of 45 kW
4.3.1
Mounting with fixing brackets (standard)
Mounting material required from the scope of supply:
Description
Use
Quantity
Fixing bracket
Drive controller fixing
4
Hexagon head cap screw M8 × 16 mm
(DIN 933)
Mounting of fixing bracket to the drive controller
4
Washer
Æ 8.4 mm (DIN 125)
For hexagon head cap screw
4
Spring washer
Æ 8 mm (DIN 127)
For hexagon head cap screw
4
Controller variant "2xx" (without fully assembled footprint filter)
For this mounting variant you require controller type E82EVxxxK4B2xx.
)
Note!
Before assembling the controller, please read the documentation for the
components connected on the supply side (mains choke, filter).