Extensions for automation – Lenze E82EV 8200 vector 15kW-90kW User Manual
Page 164
Extensions for automation
Modules
Mounting and dismounting function modules
l
164
EDK82EV903 DE/EN/FR 5.1
Dismounting
8200vec622
The following worksteps apply to the interfaces FIF I (at the top) and FIF II (at the bottom).
1. Disconnect the drive controller from mains and wait at least 3 minutes!
2. Carefully press the clip
0 upwards and remove the function module 3.
3. Plug the FIF cover
2 to the terminals of the interface.
– Make sure that the pins of the FIF interface are plugged correctly in the sockets of
the FIF cover and are not bent.
– Without the FIF cover, the controller is inhibited.
4. Plug on the blanking cover
1.
5. Push the blanking cover
1 until the clip 0 locks into place.
– If no function module is plugged on, the controller without FIF cover
2 and
blanking cover
1 must not be commissioned (dangerous electrical voltage at the
FIF interface).