Commissioning, Important codes for quick commissioning – Lenze E82EV 8200 vector 15kW-90kW User Manual

Page 182

Advertising
background image

Commissioning

Important codes for quick commissioning

7

l

182

EDK82EV903 DE/EN/FR 5.1

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0140* Additive

frequency
setpoint
(NSET1−NADD)

0.00

−650.00

{0.02 Hz}

650.00

l

Selection via

j function of the

keypad or parameter channel

l

Acts additively on the main
setpoint

l

Value will be stored when
switching the mains or removing
the keypad

l

C0140 is only transferred during
parameter set transfer with GDC
(not with keypad)

C0148*

s

Identifying
motor data

0

0

Ready

Only when the motor is cold!
1. Inhibit controller, wait until drive is

at standstill

2. Enter the correct values from the

motor nameplate in C0087, C0088,
C0089, C0090, C0091

3. Set C0148 = 1, confirm with

v

4. Enable controller:

The identification
– starts,

c goes out

– the motor "whistles" faintly but

it does not rotate!

– takes approx. 30 s
– is completed when

c is lit

again

5. Inhibit controller

1

Start identification

l

V/f rated frequency (C0015), slip
compensation (C0021) and motor stator
inductance (C0092) are calculated and
saved

l

The motor stator resistance (C0084) =
total resistance of the motor cable and
motor is measured and saved

C0517*

v

User menu

l

After mains switching or in the

g

function the code from C0517/1 is
displayed.

l

In the Lenze setting the user menu
contains the most important codes
for commissioning the operating
mode "V/f characteristic control
with a linear characteristic"

l

If the password protection is
active, only the codes entered in
C0517 can be freely accessed

l

If less than 10 codes are required,
assign the value "0" (zero) to the
memory locations not used. Please
observe that the software
automatically assigns code C0050
to a memory location that is not
used, if it has not been explicitly
assigned to another memory
location.

1 Memory 1

50

C0050

Output frequency (MCTRL1−NOUT)

2 Memory 2

34

C0034

Range of analog setpoint selection

3 Memory 3

7

C0007

Fixed configuration of digital input signals

4 Memory 4

10

C0010

Minimum output frequency

5 Memory 5

11

C0011

Maximum output frequency

6 Memory 6

12

C0012

Acceleration time main setpoint

7 Memory 7

13

C0013

Deceleration time main setpoint

8 Memory 8

15

C0015

V/f rated frequency

9 Memory 9

16

C0016

V

min

boost

10 Memory 10

2

C0002

Parameter set transfer

Possible entries for C0517

xxxx

All codes apart from the codes labelled
with "(A)".

Syntax:
Codes: C0517/x = cccc
Subcodes: C0517/x = cccc.ss

Advertising