Important codes for quick commissioning, Commissioning – Lenze E82EV 8200 vector 15kW-90kW User Manual
Page 176
Commissioning
Important codes for quick commissioning
l
176
EDK82EV903 DE/EN/FR 5.1
7.4
Important codes for quick commissioning
The following table describes the codes mentioned in the commissioning examples. A
description of all codes can be found in the system manual, chapter "Function library".
How to read the code table
Column
Abbreviation
Meaning
Code
Cxxxx
Code Cxxxx
l
The parameter value of the code can be defined
differently within each parameter set
l
The parameter value is accepted immediately
(ONLINE)
1
Subcode 1 of Cxxxx
2
Subcode 2 of Cxxxx
*
Parameter value of the code is the same for all parameter sets and can be
changed in parameter set 1
v
Keypad E82ZBC
Changed parameter of the code or subcode will be
accepted after pressing
v
Keypad XT EMZ9371BC
Changed parameter of the code or subcode will be
accepted after pressing
T V
s
Keypad E82ZBC
Changed parameter of the code or subcode will be
accepted after pressing
v if the controller is inhibited
Keypad XT EMZ9371BC
Changed parameter of the code or subcode will be
accepted after pressing
T V if the controller is
inhibited
(A)
Code, subcode or selection only available for operation with application I/O
uSEr
Code is contained in the Lenze setting in the USER menu
Designation
Name of the code
Lenze
Lenze setting (value at delivery or after restoring the delivery status with C0002)
à
Further information can be obtained from the "IMPORTANT" column
Selection
1
{%}
99 Min. value
{unit} max. value
IMPORTANT
−
Brief, important explanations
Code
Possible settings
IMPORTANT
No.
Name
Lenze
Selection
C0002*
s
uSEr
Parameter set
management
0
0
Ready
PAR1 ... PAR4:
l
Parameter sets of the controller
l
PAR1 ... PAR4 also contain the
parameters for the function
modules standard I/O, application
I/O, AS interface, system bus (CAN)
FPAR1:
l
Module−specific parameter set of
the fieldbus function modules
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
l
FPAR1 is saved in the function
module
Restoring the
delivery status
1
Lenze setting
ð PAR1
Restore the delivery status in the
parameter set selected
2
Lenze setting
ð PAR2
3
Lenze setting
ð PAR3
4
Lenze setting
ð PAR4
31
Lenze setting
ð FPAR1
Restore the delivery status in the
fieldbus function module
61
Lenze setting
ð PAR1 + FPAR1
Restore the delivery status in the
selected parameter set of the
controller and in the fieldbus function
module
62
Lenze setting
ð PAR2 + FPAR1
63
Lenze setting
ð PAR3 + FPAR1
64
Lenze setting
ð PAR4 + FPAR1