Mechanical installation – Lenze E82EV 8200 vector 15kW-90kW User Manual

Page 132

Advertising
background image

Mechanical installation

Standard devices with a power of 55 kW
Modification of the fan module for push−through technique

4

l

132

EDK82EV903 DE/EN/FR 5.1

4.4.3

Modification of the fan module for push−through technique

For thermally separated mounting the fan module has to be rotated by 180° so that the
controller fits into the mounting cutout.

Removing the fan module

9300vec170

Fig. 4−1

Removing the fan module from the controller

1. Remove both screws.

The screws connect the fans to the supply voltage.

2. Remove the 4 screws for fixing the fan module on each side.

3. Pull back the fan module and carefully remove it to the top.

Make sure that the threaded sleeves do not touch the housing edge. They may break
off.

Modifying the threaded sleeves on the fan module

9300vec171

Fig. 4−2

Modifying the threaded sleeves for the voltage supply of the fans

1. Remove the threaded sleeves.

2. Screw−in the threaded sleeves on the opposite side and fasten them.