Mechanical installation – Lenze E82EV 8200 vector 15kW-90kW User Manual
Page 135
![background image](/manuals/565990/135/background.png)
Mechanical installation
Standard devices in the power range 75 ... 90 kW
Mounting with fixing brackets (standard)
l
135
EDK82EV903 DE/EN/FR 5.1
Controller variant "2xx" (without fully assembled footprint filter)
For this mounting variant you require controller type E82EVxxxK4B2xx.
)
Note!
Before assembling the controller, please read the documentation for the
components connected on the supply side (mains choke, filter).
2
3
1
³
100 mm
a
c
e
k
b1
d2
d1
d
³
100mm
l
L
e
m
g
M 8
max. 15 mm
M 8
f
g
a
18 Nm
159.3 lb-in
0
³ 50 mm
³ 50 mm
c1
8200vec273
Loosen both screws to be able to remove the housing cover. The assembly kit is located under
the housing cover.
Installation of mounting angles
Dimensions
0
Arrange the controllers side by side with spacing to be able to disassemble the eyebolts.
Dimensions [mm]
8200 vector
a
b1
c
c1
d
d1
d2
e
1)
g
k
m
E82EV753K4B2xx
450
680
393
28.5
750
38
702
285
11
28
18
E82EV903K4B2xx
1)
If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 8 mm.