Lenze SCD Series User Manual

Page 29

Advertising
background image

26

Press

Mode

to display present

parameter setting (example setting
is 20.0)

Upper right decimal point blinks

Use " and ! to scroll to the desired
parameter number (the example is
Parameter 19 - ACCELERATION
TIME)

NOTE: If the display flashes “Er”, the password was incorrect, and the process to enter the password
must be repeated.

Use the " and ! buttons to scroll to the desired parameter number. In the example below, Parameter
19 is being displayed, which is the ACCELERATION TIME of the drive:

Once the desired parameter number is found, press the

Mode

button to display the present parameter

setting. The upper right-hand decimal point will begin blinking, indicating that the present parameter
setting is being displayed, and that it can be changed by using the " and ! buttons.

Use " and ! to change setting
(example setting changed to 30.0)

Press

Mode

to store new setting

Pressing the

Mode

will store the new setting and also exit the PROGRAM mode. To change another

parameter, press the

Mode

key again to re-enter the PROGRAM mode (the parameter menu will be

accessed at the parameter that was last viewed or changed before exiting). If the

Mode

key is pressed

within two minutes of exiting the PROGRAM mode, the password is not required access the parameters.
After two minutes, the password must be entered in order to access the parameters again.

Advertising