Lenze SCD Series User Manual
Page 72
![background image](/manuals/566052/72/background.png)
69
NOTE: See next page for Parameter List
B.5.6
PARAMETER OBJECT - CLASS 0x0F
SERVICE
SERVICE
CODE
CLASS
INSTANCE
NAME
0x0E
YES
YES
Get_Attribute_Single
0x10
NO
YES
Set_Attribute_Single
DEVICENET CONNECTION CLASS SERVICES
IMPLEMENTED FOR
ATTRIBUTE ID ACCESS RULE
NAME
DATA TYPE
VALUE
1
GET
REVISION
UINT
2
2
GET
NO. OF INSTANCES
UINT
150
8
GET
PARAMETER CLASS
WORD
0x03
DESCRIPTOR
9
GET
CONFIGURATION
UINT
0
ASSEMBLY #
10
GET
NATIVE LANGUAGE
UINT
0 = English
1
GET / SET
PARAMETER VALUE
2
GET
LINK PATH SIZE
USINT
0 to 2
3
GET
LINK PATH
DNET PATH
4
GET
DESCRIPTOR
WORD
5
GET
DATA TYPE
USINT
6
GET
DATA SIZE
USINT
PARAMETER CLASS ATTRIBUTES
INSTANCE 0
INSTANCE 1 - 150
NUMBER OF INSTANCES (PARAMETERS): 150
SERVICE
SERVICE
CODE
CLASS
INSTANCE
NAME
0x0E
YES
YES
Get_Attribute_Single
0x10
NO
YES
Set_Attribute_Single
PARAMETER CLASS SERVICES
IMPLEMENTED FOR