Storage Temperature

-20 to 70 C

Ambient Operating Temperature

0 to 50 C (up to 6 kHz carrier, derate above 6 kHz)

Ambient Humidity

< 95% (non-condensing)

Maximum Altitude

3300 ft (1000 m) above sea level (without derating)

Input Line Voltages

208/240 Vac, 400/480 Vac, 480/590 Vac

Input Voltage Tolerance

+10%, -15%

Input Frequency Tolerance

48 to 62 Hz

Output Wave Form

Sine Coded PWM

Output Frequency

0 - 240 Hz (consult factory for higher output frequencies)

Carrier Frequency

4 kHz to 10 kHz

Service Factor

1.00 (up to 6 kHz carrier, derate above 6 kHz)

Efficiency

Up to 98%

Power Factor (displacement)

0.96 or better

Overload Current Capacity

150% for 60 seconds, 180% for 30 seconds

Speed Reference Follower

0-10 VDC, 4-20 mA

Control Voltage

15 VDC

Power Supply for Auxiliary Relays

50 mA at 12 VDC

Analog Outputs

0 - 10 VDC or 2 - 10 VDC: Proportional to frequency or load

Digital Outputs

Open-collector outputs: 50 mA at 30 VDC

4.0

SCD SPECIFICATIONS

Supply Voltage

11 to 25 VDC

Current Consumption (max)

50 mA @ 11 VDC

Baud Rates and Max Distance

125 kbps - 500 m (1640 ft)

250 kbps - 250 m (820 ft)

500 kbps - 100 m (328 ft)

4.1

DEVICENET

TM

ELECTRICAL SPECIFICATIONS