Lenze SCD Series User Manual

Page 73

Advertising
background image

70

ID NO.

PARAMETER

OBJECT MAPPING

1

OUTPUT FREQUENCY (0.1 Hz)

0x0F-1-1

2

OUTPUT VOLTAGE (V)

0x2A-1-17

3

OUTPUT CURRENT (100mA)

0x2A-1-9

4

OUTPUT POWER (W)

0x2A-1-15

5

INPUT VOLTAGE (V)

0x2A-1-16

6

COMMANDED FREQUENCY (0.1 Hz)

0x0F-6-1

7

PRESENT FAULT DNET CODE

0x29-1-13

8

PRESENT FAULT NAME

0x0F-8-1

9 - 16

RESERVED

17

BUS OFF ERROR

0x03-1-3

18

BUS OFF COUNT

0x03-1-4

19

DEVICENET IDLE MODE

0x0F-19-1

20

CONTROL SOURCE

0x29-1-5

21

RUN FORWARD

0x29-1-3

22

RUN REVERSE

0x29-1-4

23

FAULT RESET

0x29-1-12

24

DEVICENET PRESET COMMAND

0x0F-24-1

25

SPEED REFERENCE

0x2A-1-4

26

NETWORK REFERENCE FREQUENCY

0x0F-26-1

27

STATUS OF RUN/STOP CONTROL SRC

0x29-1-15

28

STATUS OF SPEED REFERENCE

0x2A-1-29

29

ACTUAL DIRECTION

0x0F-29-1

30

RUN STATE

0x0F-30-1

31

SPEED SOURCE

0x0F-31-1

32

RESERVED

33

AT REFERENCE STATUS

0x2A-1-3

34

RESERVED

35

COS STATUS

0x0F-35-1

36

COS MASK

0x0F-36-1

37

RESERVED

38

KEYPAD COMMAND FREQUENCY

0x0F-38-1

39

RESERVED

40

ACT EEPROM VERSION - PARAMETER VERSION ID NUMBER

0x0F-40-1

PARAMETER OBJECT INSTANCE (PARAMETER LIST)

NOTE: THE SAME PARAMETERS ARE PRESENT IN THE EDS FILE