Lenze SCD Series User Manual
Page 96
![background image](/manuals/566052/96/background.png)
93
DNET Par. ID 150 - DEVICENET DIAGNOSTICS (ACT Parameter C10) (READ ONLY):
See tables below:
NO.
0
LOCAL CONTROL
1
NETWORK CONTROL
2
ACT PARAMETER 14 - CONTROL SET TO "NETWORK ONLY" BUT NETWORK
CONTROL IS NOT SET.
DESCRIPTION
LEFT DIGIT - CONTROL STATUS
NO.
NO.
0
NETWORK OFF
5
NETWORK CONNECTED
1
NETWORK NOT CONNECTED
6
2
NETWORK CONNECTION TIMEOUT
7
3
COMMUNICATION FAULTED
8
DUPLICATE MAC ID FAILURE
4
9
NETWORK CRITICAL LINK FAILURE
DESCRIPTION
DESCRIPTION
MIDDLE DIGIT - NETWORK STATUS
NO.
NO.
0
I/O CONNECTION OFF
5
I/O ACTIVE
1
I/O CONNECTION IDLE STATE
6
2
7
3
I/O FAULTED
8
4
9
I/O CRITICAL ERROR
DESCRIPTION
DESCRIPTION
RIGHT DIGIT - I/O STATUS
NO.
NO.
0
NON-STANDARD MOTOR
6
WOUND ROTOR INDUCTION
1
PM DC MOTOR
7
SQUIRREL CAGE INDUCTION
2
FC DC MOTOR
8
STEPPER MOTOR
3
PM SYNCHRONOUS MOTOR
9
SINUSOIDAL PM BL
4
FC SYNCHRONOUS MOTOR
10
TRAPEZOIDAL PM BL
5
SWITCHED RELUCTANCE
DESCRIPTION
DESCRIPTION
MOTOR TYPES
DNET Par. ID 149 - DEVICENET MOTOR TYPE (ACT Parameter C09): See table below: