B.5.10 AC / DC DRIVE OBJECT - CLASS 0x2A
ATTRIBUTE ID ACCESS RULE
NAME
DATA TYPE
VALUE
1
GET
REVISION
UINT
1
2
GET
NUMBER OF
UINT
1
INSTANCES
1
GET
NO. OF SUPPORTED
USINT
12
ATTRIBUTES
2
GET
ATTRIBUTE LIST
ARRAY
3
GET
AT REFERENCE
BOOL
Speed At Ref
4
GET / SET
NET REFERENCE
BOOL
0 = Local Spd Ref
1 = Net Spd Ref
6
GET
DRIVE MODE
USINT
1=Open Loop Spd Control
7
GET
ACTUAL SPEED
INT
Actual Speed (RPM)
8
GET / SET
SPEED REFERENCE
INT
Speed Reference (RPM)
9
GET
MOTOR PHASE
INT
Actual Current (0.1 A)
CURRENT
15
GET
ACTUAL OUTPUT
INT
Actual Power (W)
POWER
16
GET
INPUT VOLTAGE
INT
(V)
17
GET
OUTPUT VOLTAGE
INT
(V)
29
GET
STATUS OF SPEED
INT
0 = Local Spd Ref
REFERENCE
1 = Net Spd Ref
INSTANCE 1
AC / DC DRIVE CLASS ATTRIBUTES
INSTANCE 0
SERVICE
SERVICE
CODE
CLASS
INSTANCE
NAME
0x0E
YES
YES
Get_Attribute_Single
0x10
NO
YES
Set_Attribute_Single
AC DRIVE CLASS SERVICES
IMPLEMENTED FOR